T202L

Halfbridge Transducer with 73.75 mm/Vmm sensitivity and ± 1 mm measuring stroke, Pneumatic push with air gap seal. Cable 2 m, cable exit radial.

Articlenumber
1001447
Product Image
Properties
  • Total Stroke, Pretravel, Pretravel default setting, Bearing, Lifetime, Tip rotation, Temperatur range, Mounting position, Tip, Bellow, Body diameter, Plug, Cable, Cable information
    Total Stroke
    2.5 mm
    Pretravel
    not adjustable
    Pretravel default setting
    - 1.25 mm
    Bearing
    Ball bearing, no side-play
    Lifetime
    > 10 Mio. Cycles
    Tip rotation
    1° over full stroke
    Temperatur range
    -10 to +65 °C, storage and operation
    Mounting position
    any
    Tip
    2 mm tungsten carbide ball, M2.5 fixing thread, exchangeable
    Bellow
    none (air gap seal)
    Body diameter
    8h6
    Plug
    5 pin, 240°
    Cable
    PUR shielded, Length 2 m
    Cable information
    Outer- Ø 4.0 mm, drag chain compatible
  • Advance, Lift off, Pressure Pmax, Pressure P application, Spring rate information
    Advance
    pneumatic
    Lift off
    return spring
    Pressure Pmax
    4.5 bar
    Pressure P application
    1.1 bar
    Spring rate information
    apx. 1.0 N at 1.1 bar / apx. 0.6 N at 0.8 bar (at el. zero)
  • Repeatability, Linearity error
    Repeatability
    0.02 µm
    Linearity error
    0.6% FS ± 1000 µm range (at 20 °C ± 1°C)
  • Sensitivity, Setting, Amplifier input load, Drive frequency, Supply voltage, Coil scheme
    Sensitivity
    73.75 mV/(Vmm)
    Setting
    1:1
    Amplifier input load
    2 kOhm Input resistance, ± 0.1%
    Drive frequency
    13.0 kHz ±5%
    Supply voltage
    3.0 V ±0.5%RMS
    Coil scheme
    Halfbridge, TESA® compatible
  • Documents information
    Documents information
    All drawings and 3D models are shown in "electrical zero" position.