T524L

Halfbridge Transducer with 73.75 mm/Vmm sensitivity, ± 1 mm measuring stroke and 8 mm overtravel, Pretravel adjustable. Pneumatic push with air gap seal. Cable 2 m, cable exit radial.

Articlenumber
1002131
Product Image
Properties
  • Total Stroke, Measuring stroke (symmetrical ±), Pretravel, Pretravel default setting, Bearing, Lifetime, Tip rotation, Temperatur range, Mounting position, Tip, Bellow, Body diameter, Plug, Cable, Cable information
    Total Stroke
    10.6 mm
    Measuring stroke (symmetrical ±)
    1.0 mm
    Pretravel
    adjustable
    Pretravel default setting
    + 8.0 mm
    Bearing
    Ball bearing, no side-play
    Lifetime
    > 10 Mio. Cycles
    Tip rotation
    1° over full stroke
    Temperatur range
    -10 to +65 °C, storage and operation
    Mounting position
    any
    Tip
    3 mm tungsten carbide ball, M2.5 fixing thread, exchangeable
    Bellow
    none (air gap seal)
    Body diameter
    8h6
    Plug
    5 pin, 240°
    Cable
    PUR shielded, Length 2 m
    Cable information
    Outer- Ø 4.0 mm, drag chain compatible
  • Advance, Lift off, Pressure Pmax, Pressure P application, Spring rate information
    Advance
    pneumatic
    Lift off
    return spring
    Pressure Pmax
    4.5 bar
    Pressure P application
    1.7 bar
    Spring rate information
    apx. 1.6 N at 1.7 bar / apx. 1.0 N at 1.3 bar (at el. zero)
  • Repeatability, Linearity error
    Repeatability
    0.02 µm
    Linearity error
    0.25% FS ± 1000 µm range (at 20 °C ± 1°C)
  • Sensitivity, Setting, Amplifier input load, Drive frequency, Supply voltage, Coil scheme
    Sensitivity
    73.75 mV/(Vmm)
    Setting
    1:1
    Amplifier input load
    2 kOhm Input resistance, ± 0.1%
    Drive frequency
    13.0 kHz ±5%
    Supply voltage
    3.0 V ±0.5%RMS
    Coil scheme
    Halfbridge, TESA® compatible
  • Documents information
    Documents information
    All drawings and 3D models are shown in "electrical zero" position.