T502FDG

Intelligent transducer with integrated signal conditioning and digital interface, Measuring stroke ± 5 mm, Pretravel not adjustable. Spring push. Plug DIN M5, cable exit radial.

Articlenumber
1004862
Product Image
Properties
  • Total Stroke, Measuring stroke, Pretravel default setting, Bearing, Lifetime, Tip rotation, Temperatur range, Mounting position, Tip, Bellow, Body diameter, Plug, Cable
    Total Stroke
    10.6 mm
    Measuring stroke
    ± 5.0 mm
    Pretravel default setting
    symmetrical, not adjustable
    Bearing
    Ball bearing, no side-play
    Lifetime
    > 10 Mio. Cycles
    Tip rotation
    1° over full stroke
    Temperatur range
    -10 to +65 °C, storage and operation
    Mounting position
    any
    Tip
    3 mm tungsten carbide ball, M2.5 fixing thread, exchangeable
    Bellow
    FPM / FKM
    Body diameter
    8h6
    Plug
    DIN M5
    Cable
    PUR shielded, Pig-Tail Length 200 mm
  • Advance, Lift off, Spring rate, Spring rate information, Spring rate optional
    Advance
    spring push
    Lift off
    no
    Spring rate
    1.00 N
    Spring rate information
    at electrical zero, tolerance ± 20%
    Spring rate optional
    1.6 N
  • Repeatability, Error limit, Measuring rate, Power supply, Power consumption
    Repeatability
    0.05 µm
    Error limit
    ±2.0 µm (at 20 °C ±1 °C)
    Measuring rate
    4000 measurements/ sec
    Power supply
    5V
    Power consumption
    120 mW (operating) 15 mW (stand-by)
  • Measuring system, Data interface, Connection to electronic device, Transmission rates, Data information
    Measuring system
    Plunger, Inductive Half Bridge. Integrated conditioning with system error correction
    Data interface
    Communication protokol for digital HIRT transducers. Open protocol, point-to-point connection based on RS485, termination 120 Ohm
    Connection to electronic device
    Plug connection on M5 standard, 4-pin with screw-lock
    Transmission rates
    9600 bit/s, 115200 bit/s, 10 kbit/s, 500 kbit/s and optional 1Mbit/s und 2 Mbit/s
    Data information
    Sensor information for testing management, SPS-profiles /-objects and maintenance
  • Documents information
    Documents information
    All drawings and 3D models are shown in "electrical zero" position.